Line Interactive UPS - LPS-600R |
|
Feature:
- Line Interactive UPS Design
- CPU Control
- AVR Function
- DC Start
- Full Protection
|
|
Specification:
|
Model |
LPS-600R |
|
Capacity |
600VA/360W |
|
Input |
Voltage Range |
90~140VAC±3% or 175~265VAC±3% |
|
Nominal Voltage |
110/120VAC or 220/230/240VAC |
|
Frequency |
50/60Hz±5% |
|
Max. Input Current |
6.5A (With Bypass Socket) |
|
Output |
Nominal Voltage |
110/120VAC or 220/230/240VAC |
|
Voltage Range |
Normal Mode |
110/120VAC or 220/230/240VAC+10%-15% |
|
Battery Mode |
110/120VAC or 220/230/240VAC±10% |
|
Frequency |
Normal Mode |
Synchronized |
|
Battery Mode |
50/60Hz±0.5 |
|
Max. Output Current |
2.7A |
|
Overload Capacity |
110~120% (60 Seconds) |
|
Wave Form |
Step Wave |
|
Power Factor |
0.6 |
|
Efficiency |
|
>80% |
|
Transfer Time |
|
<10ms |
|
Battery |
Battery Type |
12V/7Ah*1pcs |
|
Back-up Time |
2.5Mins (Full Load); 8Mins (Half Load) |
|
Recharge Time |
<12 hours to 90% after compete discharge |
|
Display |
LED |
Normal, Battery, Unusual |
|
Alarm |
AC Unusual, Battery Low, Overload, Short Circuit, PCB Failed |
Sounding for 60 seconds |
|
Interface |
DB-9 |
Standard |
|
Cold Start |
|
Yes |
|
Protection |
Surge and Filtering |
High Voltage, Low Voltage, Surge, Spike |
|
Overload |
Yes |
|
Battery Low |
Yes |
|
Short Circuit |
Output Auto Cutoff, Buzzer Beeping |
|
EMI Filter |
Yes |
|
Tel/Fax/Modem Jack |
Yes |
|
Environment |
Operating Temperature |
0゚C~40゚C |
|
Humidity |
0~90% at Non-condensing |
|
Audible Noise |
<50dB at 1 meter |
|
Physical |
Dimension (D*W*H) |
515X110X92 |
|
Net Weight |
8.0kgs |
|
| |
Copyright © 1988-